Mulberry Park

download as PDF
Download
as PDF
Mulberry Park is a Passivhaus new-build project made up of 4 units in Bath, Somerset. The housing was designed by Powell Dobson Architects and was completed in 2020.
Images Graphs Figures Description Strategies Building

Mulberry Park : Project images

Click on image to preview full size

Mulberry_Park_Aerial_Credit_Curo_Anna_Barclay.jpg
CO2 emissionsPrimary energy requirement
Energy target
PassivHaus

Energy and fuel use

Fuel use by type
Primary energy requirement
CO2 emissions
Renewables

Measured data from renewable generation is not yet available.

Fuel use

 Pre-developmentForecastMeasured
Electricity use - - -
Natural gas use- - -
Oil use- - -
LPG use- - -
Wood use- - -
Other Fuel - - -
 Pre-developmentForecastMeasured
Primary energy requirement - - -
Annual CO₂ emissions - - -
Annual space heat demand - - 16 kWh/m².yr

Renewable energy

Electricity generationForecastMeasured
Renewables Technology--
Other Renewables Tech--
Electricity consumed by generation --
Primary energy requirement
offset by renewable generation
--
Annual CO₂ emissions
offset by renewable generation
--

Calculation and targets

Whole house energy calculation method
Other whole house calculation method-
Energy target PassivHaus
Other energy targets-
Forecast heating load -

Airtightness

 DateResult
Pre-development air permeability test--
Final air permeability test--

Project description

StageOccupied
Start date
Occupation date01 January 2021
Location Bath Somerset  England
Build typeNew build
Building sectorPrivate Residential
Property typeMid Terrace
Construction typeSoftwood frame
Other construction typeTimber twin stud construction, 300mm Warmcel insultation
Party wall construction
Floor area 343
Floor area calculation method Treated Floor Area (PHPP)
Building certification  Passivhaus certified building Passivhaus certified building

Project Team

OrganisationCuro Group
Project lead person
Landlord or ClientCuro Places
ArchitectPowell Dobson Architects
Mechanical & electrical consultant CVC Direct
Energy consultantPowell Dobson Architects
Structural engineerPowell Dobson Architects
Quantity surveyor
ConsultantWARM
ContractorCuro Group

Design strategies

Planned occupancy
Space heating strategyGas Combi Boiler and radiators.
Water heating strategyGas Combi Boiler
Fuel strategy
Renewable energy strategy
Passive Solar strategy
Space cooling strategy
Daylighting strategy
Ventilation strategyBrink Flair 325, Mechanical Ventilation Heat Recovery
Airtightness strategy
Strategy for minimising thermal bridges
Modelling strategy
Insulation strategy
Other relevant retrofit strategies
Contextual information

Building services

Occupancy
Space heating
Hot water
Ventilation
Controls
Cooking
Lighting
Appliances
Renewable energy generation system
Strategy for minimising thermal bridges

Building construction

Storeys
Volume -
Thermal fabric area -
Roof description Traditional cold roof construction, with 600mm of mineral wool laid over base chord of trusses.
Roof U-value 0.06 W/m² K
Walls description Exterior wall Timber twin stud construction, fully filled with 300mm Warmcel insulation.
Walls U-value -
Party walls description
Party walls U-value -
Floor description Basement floor / floor slab:150mm Raft foundation with 300mm XPS insulation below.
Floor U-value 0.12 W/m² K
Glazed doors description Generally: Saint-Gobain Glass - SGG PLANITHERM XN II
Glazed doors U-value 0.52 W/m² K -
Opaque doors description
Opaque doors U-value - -
Windows description
Windows U-value - -
Windows energy transmittance (G-value) -
Windows light transmittance -
Rooflights description
Rooflights light transmittance -
Rooflights U-value -