Measured data from renewable generation is not yet available.
| Pre-development | Forecast | Measured | |
| Electricity use | - | - | - |
|---|---|---|---|
| Natural gas use | - | - | - |
| Oil use | - | - | - |
| LPG use | - | - | - |
| Wood use | - | - | - |
| mains gas | - | - | - |
| Pre-development | Forecast | Measured | |
| Primary energy requirement | - | - | - |
|---|---|---|---|
| Annual CO₂ emissions | - | - | - |
| Annual space heat demand | - | 18.3 kWh/m².yr | - |
| Electricity generation | Forecast | Measured |
|---|---|---|
| Renewables Technology | - | - |
| Other Renewables Tech | - | - |
| Electricity consumed by generation | - | - |
| Primary energy requirement offset by renewable generation | - | - |
| Annual CO₂ emissions offset by renewable generation | - | - |
| Whole house energy calculation method | PHPP |
|---|---|
| Other whole house calculation method | - |
| Energy target | Retrofit for the Future |
| Other energy targets | - |
| Forecast heating load | 12 W/m² demand |
| Date | Result | |
| Pre-development air permeability test | - | 12.32m³/m².hr @ 50 Pascals |
|---|---|---|
| Final air permeability test | - | 6.46m³/m².hr @ 50 Pascals |
| Stage | Under construction |
|---|---|
| Start date | 03 May 2010 |
| Occupation date | 06 September 2010 |
| Location | Newcastle upon Tyne England |
| Build type | Refurbishment |
| Building sector | Public Residential |
| Property type | Semi-Detached |
| Construction type | Masonry Cavity |
| Other construction type | 50mm cavity width |
| Party wall construction | 250mm solid brick |
| Floor area | 99.8 m² |
| Floor area calculation method | Treated Floor Area (PHPP) |
| Building certification |
| Organisation | Newcastle City Council |
|---|---|
| Project lead person | Newcastle City Council |
| Landlord or Client | Your Homes Newcastle / Newcastle City Council |
| Architect | DKS Architects / Newcastle City Council |
| Mechanical & electrical consultant | ARUP |
| Energy consultant | Vanguard Homes / ARUP |
| Structural engineer | Vanguard Homes / Newcastle City Council |
| Quantity surveyor | Vanguard Homes / Newcastle City Council |
| Consultant | Institute of Energy and Sustainable Development, De Montfort University |
| Contractor | t.b.d. |
| Planned occupancy | Advertised as Passive House with incentives to attract willing family tenant. Proposed as decant unit to act as education / demonstration through occupany. |
|---|---|
| Space heating strategy | MVHR unit with backup mains gas. |
| Water heating strategy | Solar water heating. |
| Fuel strategy | Mains gas and electricity |
| Renewable energy strategy | No requirement for renewable electricity to meet Passive House standard. |
| Passive Solar strategy | Rear south facing windows with shading / external landscaping. |
| Space cooling strategy | Natural ventilation combined with MVHR unit for summer cooling. |
| Daylighting strategy | Kitchen to achieve minimum daylight factor of 2% |
| Ventilation strategy | Openable windows and MVHR controlled on a room by room basis. |
| Airtightness strategy | External airtight membrane colocated with with external insulation layer. MMC used in bays and pre fitted replacement windows panels. |
| Strategy for minimising thermal bridges | External insulated panel with overlapping layers and taped joints. |
| Modelling strategy | Whole house modelling in PHPP 2007. Phased assessment based upon proposed sequence of interventions. |
| Insulation strategy | External insulation to external brick facing to achieve U-value of 0.12 W/m2K. Ceiling insulation with U-value of 0.12 W/m2K and retention of cold roof. |
| Other relevant retrofit strategies | |
| Contextual information | Proposed work in advance of wider retrofit programme for the estate and informed by transferable detailing, materials and scalign of cost benefits. |
| Occupancy | NULL |
|---|---|
| Space heating | NULL |
| Hot water | NULL |
| Ventilation | NULL |
| Controls | NULL |
| Cooking | NULL |
| Lighting | NULL |
| Appliances | NULL |
| Renewable energy generation system | NULL |
| Strategy for minimising thermal bridges | NULL |
| Storeys | |
|---|---|
| Volume | - |
| Thermal fabric area | - |
| Roof description | NULL |
| Roof U-value | 0.00 W/m² K |
| Walls description | NULL |
| Walls U-value | 0.00 W/m² K |
| Party walls description | NULL |
| Party walls U-value | 0.00 W/m² K |
| Floor description | NULL |
| Floor U-value | 0.00 W/m² K |
| Glazed doors description | NULL |
| Glazed doors U-value | 0.00 W/m² K - |
| Opaque doors description | NULL |
| Opaque doors U-value | 0.00 W/m² K - |
| Windows description | NULL |
| Windows U-value | 0.00 W/m² K - |
| Windows energy transmittance (G-value) | - |
| Windows light transmittance | - |
| Rooflights description | NULL |
| Rooflights light transmittance | - |
| Rooflights U-value | 0.00 W/m² K |