Bowker Street: Terrace C

download as PDF
Download
as PDF
24 Homes. 12 to AECB Silver.Terrace A = 8 AECB Silver homesTerrace C = 4 AECB Silver homes
Images Graphs Figures Description Strategies Building

Bowker Street: Terrace C : Project images

Click on image to preview full size

Floor_to_wall_junction__airtightness_measures_visible1.jpg
Window_in_wall_detail__jamb_with_airtightness_measures_visible3.jpg
Elevations_TerraceC1.jpg
Intermediate_floor_to_wall_junction__airtightness_measures_visible1.jpg
MVHR_installation_showing_ducts__duct_insulation1.jpg
Elevations_TerraceC3.jpg
CO2 emissionsPrimary energy requirement
Energy target
AECB Silver

Energy and fuel use

Fuel use by type
Primary energy requirement
CO2 emissions
Renewables

Measured data from renewable generation is not yet available.

Fuel use

 Pre-developmentForecastMeasured
Electricity use - - -
Natural gas use- - -
Oil use- - -
LPG use- - -
Wood use- - -
Other Fuel - - -
 Pre-developmentForecastMeasured
Primary energy requirement - - -
Annual CO₂ emissions - - -
Annual space heat demand - 34 kWh/m².yr -

Renewable energy

Electricity generationForecastMeasured
Renewables Technology--
Other Renewables Tech--
Electricity consumed by generation --
Primary energy requirement
offset by renewable generation
--
Annual CO₂ emissions
offset by renewable generation
--

Calculation and targets

Whole house energy calculation method PHPP
Other whole house calculation method-
Energy target AECB Silver
Other energy targets-
Forecast heating load 17 W/m² demand

Airtightness

 DateResult
Pre-development air permeability test--
Final air permeability test11 September 20141.48m³/m².hr @ 50 Pascals

Project description

StageOccupied
Start date
Occupation date
Location Salford Manchester  England
Build typeNew build
Building sectorPublic Residential
Property typeMid Terrace
Construction typeSoftwood frame
Other construction typeBrick, cavity, timber frame
Party wall construction
Floor area 300
Floor area calculation method Treated Floor Area (PHPP)
Building certification  AECB silver standard certified building AECB silver standard certified building

Project Team

Organisation
Project lead personIdentity Consult
Landlord or ClientCountour Housing Group
ArchitectAinsley Gommon
Mechanical & electrical consultant Green Building Store
Energy consultantLEAP: Low Energy Architectural Practice
Structural engineer
Quantity surveyor
Consultant
ContractorSeddon Construction

Design strategies

Planned occupancyStandard residential occupancy
Space heating strategyGas condensing boiler to radiators
Water heating strategyGas condensing boiler
Fuel strategyNatural gas
Renewable energy strategy
Passive Solar strategySouthern orientation
Space cooling strategyOpenable windows
Daylighting strategy
Ventilation strategyWindows for summer ventilation.MVHR for winter ventilation.
Airtightness strategy OSB with taped joints.Membranes with taped joints to key locations.
Strategy for minimising thermal bridges Minimise thermal briding where possible. Account for thermal bridges where they have not been addressed in a robust fashion.
Modelling strategyPHPP
Insulation strategyAccount for timber fraction.
Other relevant retrofit strategies
Contextual information

Building services

Occupancy
Space heating
Hot water
Ventilation
Controls
Cooking
Lighting
Appliances
Renewable energy generation system
Strategy for minimising thermal bridges

Building construction

Storeys
Volume -
Thermal fabric area -
Roof description
Roof U-value -
Walls description
Walls U-value -
Party walls description
Party walls U-value -
Floor description
Floor U-value -
Glazed doors description
Glazed doors U-value - -
Opaque doors description
Opaque doors U-value - -
Windows description
Windows U-value - -
Windows energy transmittance (G-value) -
Windows light transmittance -
Rooflights description
Rooflights light transmittance -
Rooflights U-value -

Bowker Street: Terrace C : Download Files